{"created":"2024-10-25T05:42:34.913746+00:00","id":2012214,"links":{},"metadata":{"_buckets":{"deposit":"4499018a-8cbc-4df5-8a9a-957b0a973e8c"},"_deposit":{"created_by":7,"id":"2012214","owners":[7],"pid":{"revision_id":0,"type":"depid","value":"2012214"},"status":"published"},"_oai":{"id":"oai:ocu-omu.repo.nii.ac.jp:02012214","sets":["1623632832836:1721264204516","1721185054892:1721627749192:1721627798259:1721627946330"]},"author_link":[],"item_1617186331708":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Changes in Pore Structure and Enhanced Durability of Concrete by the Use of Permeable Forms","subitem_title_language":"en"}]},"item_1617186419668":{"attribute_name":"作成者","attribute_type":"creator","attribute_value_mlt":[{"creatorAffiliations":[{"affiliationNames":[{"affiliationName":"Osaka City University, Technical Research Institute Asanuma Corporation","affiliationNameLang":"en"}]}],"creatorNames":[{"creatorName":"Tatematsu, Kazuhiko","creatorNameLang":"en"},{"creatorName":"タテマツ, カズヒコ","creatorNameLang":"ja-Kana"},{"creatorName":"立松, 和彦","creatorNameLang":"ja"}]},{"creatorAffiliations":[{"affiliationNames":[{"affiliationName":"Technical Research Institute Asanuma Corporation","affiliationNameLang":"en"}]}],"creatorNames":[{"creatorName":"Ishihara, Seiichiro","creatorNameLang":"en"},{"creatorName":"イシハラ, セイチロウ","creatorNameLang":"ja-Kana"},{"creatorName":"石原, 誠一郎","creatorNameLang":"ja"}]},{"creatorAffiliations":[{"affiliationNames":[{"affiliationName":"Osaka City University","affiliationNameLang":"en"}]}],"creatorNames":[{"creatorName":"Yamada, Masaru","creatorNameLang":"en"},{"creatorName":"ヤマダ, マサル","creatorNameLang":"ja-Kana"},{"creatorName":"山田, 優","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"1000010047293","nameIdentifierScheme":"KAKEN2","nameIdentifierURI":"https://nrid.nii.ac.jp/nrid/1000010047293/"},{"nameIdentifier":"read0020638","nameIdentifierScheme":"RESEARCHMAP","nameIdentifierURI":"https://researchmap.jp/read0020638"}]}]},"item_1617186609386":{"attribute_name":"主題","attribute_value_mlt":[{"subitem_subject":"permeable forms","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"pore structure","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"capillary pore","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"pore volume","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"durability","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_1617186626617":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"Permeable forms are designed to drain excess water contained in the concrete immediately after their placement. Removal of excess water not only decreases the water-cement ratio of the surface concrete, but increases the density of the concrete, and eventually enhances its durability....","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_1617186643794":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Faculty of Engineering, Osaka City University","subitem_publisher_language":"en"}]},"item_1617186920753":{"attribute_name":"収録物識別子","attribute_value_mlt":[{"subitem_source_identifier":"0078-6659","subitem_source_identifier_type":"ISSN"}]},"item_1617187056579":{"attribute_name":"bibliographic_information","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2000-12","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"110","bibliographicPageStart":"101","bibliographicVolumeNumber":"41","bibliographic_titles":[{"bibliographic_title":"Memoirs of the Faculty of Engineering Osaka City University","bibliographic_titleLang":"en"}]}]},"item_1617258105262":{"attribute_name":"item_1617258105262","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_1617265215918":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_1617353299429":{"attribute_name":"関連情報","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"AA0073257X","subitem_relation_type_select":"NCID"}}]},"item_1722232185104":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2024-09-09"}],"displaytype":"detail","filename":"DB00010268.pdf","filesize":[{"value":"1.1 MB"}],"format":"application/pdf","mimetype":"application/pdf","url":{"label":"本文","objectType":"fulltext","url":"https://ocu-omu.repo.nii.ac.jp/record/2012214/files/DB00010268.pdf"},"version_id":"1f7162da-10b9-4808-9556-69d71adae5a3"}]},"item_1725590125188":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_title":"Changes in Pore Structure and Enhanced Durability of Concrete by the Use of Permeable Forms","item_type_id":"40002","owner":"7","path":["1721627946330","1721264204516"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2024-09-09"},"publish_date":"2024-09-09","publish_status":"0","recid":"2012214","relation_version_is_last":true,"title":["Changes in Pore Structure and Enhanced Durability of Concrete by the Use of Permeable Forms"],"weko_creator_id":"7","weko_shared_id":-1},"updated":"2024-10-25T05:42:44.293945+00:00"}